| Standard Specification | Span adjustment based on standard zero point, with stainless steel 316 L diaphragm, filling liquid is silicone oil. | |||||||||||
| Performance Specification | Reference Accuracy of Adjustment Span | (Includes linearity from zero, hysteresis and repeatability): ± 0.075% | ||||||||||
| TD> 10 ( TD=Maximum span/adjustment span): ±(0.0075×TD)% | ||||||||||||
| Square root output accuracy is 1.5 times the linear reference accuracy above | ||||||||||||
| Ambient Temperature Effect | Span Code | - 20℃~65℃ Total impact | ||||||||||
| B/L | ±( 0.30×TD+ 0.20 )% ×Span | |||||||||||
| Other | ±( 0.20×TD+ 0.10 )% ×Span | |||||||||||
| Span Code | - 40℃~- 20℃ and 65℃~85℃ Total impact | |||||||||||
| B/L | ±( 0.30×TD+ 0.20 )% ×Span | |||||||||||
| Other | ±( 0.20×TD+ 0.10 )% ×Span | |||||||||||
| Over-span Effect | ±0 . 075% ×Span | |||||||||||
| Span Code | Amount of Influence | |||||||||||
| Long Term Stability | B/L | ±0.2% ×Span/ 1Year | ||||||||||
| Other | ±0.1% ×Span/ 1Year | |||||||||||
| Power Impact | ±0.001% / 10 V(12~42 V DC) | |||||||||||
| Measuring Range(Gauge pressure transmitter) | kpa/ mbar | kpa/ mbar | ||||||||||
| B | 0.6~6 /- 6~6 | 6 ~ 60 /- 60 ~ 60 | ||||||||||
| C | 2 ~ 40 /- 40 ~ 40 | 0.02 ~ 0.4 /- 0.4 ~ 0.4 | ||||||||||
| D | 2.5 ~ 250 /- 100 ~ 250 | 0.025 ~ 2.5 /- 1 ~ 2.5 | ||||||||||
| F | 30 ~ 3000 /- 100 ~ 3000 | 0.3 ~ 30 /- 1 ~ 30 | ||||||||||
| G | 100 ~ 10000 /- 1000 ~ 100000 | 1 ~ 100 /- 1 ~ 100 | ||||||||||
| H | 210 ~ 21000/-1000 ~ 210000 | 2.1 ~ 210 /- 1 ~ 210 | ||||||||||
| I | 400 ~ 40000 /-1000 ~ 400000 | 4 ~ 400 /- 1 ~ 400 | ||||||||||
| J | 600 ~ 60000 /-1000 ~ 600000 | 6 ~ 600 /- 1 ~ 60 | ||||||||||
| Measuring Range(Absolute pressure transmitter) | kpa/ mbar | kpa/ mbar | ||||||||||
| L | 2 ~ 40 /- 40 ~ 40 | 0.02 ~ 0.4 /- 0.4 ~ 0.4 | ||||||||||
| M | 2 . 5 ~ 250 /- 100 ~ 250 | 0.025 ~ 2.5 /- 1 ~ 2.5 | ||||||||||
| O | 30 ~ 3000 /- 100 ~ 3000 | 0.3 ~ 30 /- 1 ~ 30 | ||||||||||
| Span Limit | Within the upper and lower limits of the span, it can be adjusted arbitrarily; It is recommended to select a span code with the lowest possible turndown ratio to optimize performance characteristics. | |||||||||||
| Zero Point Setting | Zero point and span can be adjusted to any value within the measurement span in the table (as long as: calibration span ≥ minimum span). | |||||||||||
| Installation Location Influence | The change of the installation position parallel to the diaphragm surface will not cause zero drift effect. If the change of the installation position and the diaphragm surface exceeds 90°, the zero position effect in the span of < 0.06 Psi will occur, which can be corrected by adjusting the zero adjustment, with no range effect. | |||||||||||
| Output | Two-wire, 4~20 m ADC, HART output digital communication can be selected, linear or square root output can also be selected. Output signal limit:Imin= 3.9 m A, Imax= 20.5 m A | |||||||||||
| Alarm Current | Low report mode(Mini): 3.7 m A High report mode (Max): 21 m A Non-reporting mode (hold): keep the effective current value before the fault and report Standard setting of alarm current: high mode | |||||||||||
| Response Time | The damping constant of the amplifier part is 0.1 s and the sensor time constant is 0.1 to 1.6 s, depending on the range and range ratio.The additional adjustable time constant is 0.1 to 60 s. | |||||||||||
| Preheat Time | < 15 s | |||||||||||
| Ambient Temperature | - 40~85℃ With LCD display and fluororubber sealing ring: - 20~65℃ | |||||||||||
| Storage Temperature | - 50~85℃ With LCD display: - 40~85℃ | |||||||||||
| Pressure Limit | From vacuum to maximum range | |||||||||||
| Material | Diaphragm: Stainless Steel 316 L, C-276 alloy Process Connection: Stainless Steel 316L Transmitter Cover: Aluminum alloy material, epoxy resin sprayed on the surface Filling Fluid: Silicone Oil | |||||||||||
| Protection Class | IP67 | |||||||||||